This readme file was generated on 2026-10-29 by Lauren McHugh GENERAL INFORMATION Title of Dataset: Compiled data for Enhanced Retention of Porosity in a Three-Linker Glass-Forming Zeolitic Imidazolate Framework Available from DOI: 10.17638/datacat.liverpool.ac.uk/3094. Author/Principal Investigator Information Name: Lauren N. McHugh ORCID: 0000-0003-2032-0450 Institution: University of Liverpool Address: Department of Chemistry University of Liverpool L69 7ZD Email: L.N.Mchugh@liverpool.ac.uk Author/Associate or Co-investigator Information Name: Bethan Turner ORCID: 0009-0005-3193-0256 Institution: University of Liverpool Address: Department of Chemistry University of Liverpool L69 7ZD Email: B.Turner3@liverpool.ac.uk - Date of data collection: 2025-02 to 2026-10 - Geographic location of data collection: University of Liverpool, Liverpool, Merseyside, United Kingdom. Diamond Light Source Diamond House Harwell Science & Innovation Campus Didcot, Oxfordshire United Kingdom - Information about funding sources that supported the collection of the data: The Faculty of Science and Engineering at the University of Liverpool EPSRC Core Capability for Chemistry Research (EP/K039687/1) for the MAS NMR spectrometer funding. Japan Society of the Promotion of Science (JSPS) Postdoctoral Fellowship Blavatnik Family Foundation, as part of the Blavatnik Cambridge Postdoctoral Fellowship SHARING/ACCESS INFORMATION - Links to other publicly accessible locations of the data: CCDC deposition number 2566200. DATA & FILE OVERVIEW File List: DSC: Differential scanning calorimetry trios files Figures: TIFF files for the figures included in the paper Gas sorption: SMP and Excel files of raw sorption data H NMR PDF: pair distribution functions, input and data folder with processed data with Gudrun PXRD: XY crystal files Solid State NMR SCXRD: CIF file and crystallographic information TGA: thermogravimetric analysis, Excel and ngb files of raw data. METHODOLOGICAL INFORMATION Description of methods used for collection/generation of data: DSC: DSC measurements were conducted on TA Instruments Discovery Differential Scanning Calorimeter. Samples (ca. 7 mg) were placed in Terzo aluminium hermetic pans and sealed with a standard lid. Gas sorption: The gas uptake measurements and adsorption analysis of CO2 up to 1100 mbar at 273 K and up to 1000 mbar at 195 K were performed on a Micrometric 3 Flex 3500 Gas Sorption Analyser. Samples of ca. 100 mg were degassed in situ with N2 by heating to 383 K at a rate of 10 K min 1 under a vacuum of 10 4 mbar for 10 hours. During analysis, the temperature was controlled using a Micromeritics iso-controller chiller and cryostat. H NMR: Samples (c.a. 10 mg) were digested in DCl(35%)/D2O and D2O, and 1H NMR spectra were recorded on a Bruker Advance 400 NMR spectrometer at 400.13 MHz. PDF: Total scattering experiments were performed at beamline I15-1 of Diamond Light Source, Oxfordshire, UK (experiment CY39316). A few mg of each sample were ground using a mortar and pestle and loaded into a Kapton capillary (inner diameter: 1 mm), which was then sealed. The samples were measured at room temperature, as the X-ray wavelength was set to be 0.161669 Å. An empty capillary and the blank instrument (“air”) were also measured under the same conditions. PXRD: PXRD patterns ZIF 62, agZIF 62, ZIF UL 1, and ag ZIF UL 1 were collected in vertical transmission mode from loose powder samples held on Mylar film in aluminium well plates, using a Panalytical Empyrean equipped with a high-throughput screening XYZ stage, X-ray focusing mirror and PIXcel detector with Cu-Kα radiation (λ = 1.541 Å). Solid State NMR: All solid-state NMR measurements were recorded under Magic Angle Spinning (MAS) conditions on a Bruker Avance III HD NMR spectrometer with a 9.4 T external magnetic field, equipped with a 4 mm HXY triple-resonance MAS probe (used in double resonance mode) tuned to 1H and 13C Larmor frequencies of 400.15 MHz and 100.63 MHz on the X channel, respectively. The samples were finely ground and packed in air into 4 mm ZrO2 rotors and closed with kel-f caps. All 1H and 13C were externally referenced to adamantane at chemical shifts of 1.8 ppm1 and 29.45 ppm2 (for the upfield -CH peak), respectively. All 13C detection were performed with 1H SPINAL-64 heteronuclear decoupling at a radio frequency (rf) field amplitude of 70 kHz SCXRD: A suitable crystal was harvested in a drop of mother liquor and mounted on a Mitegen loop. This was immediately transferred to the diffractometer and placed under an open-flow helium-cooling device (Oxford Cryosystems Helix) at 30 K. Intensity data were collected on beamline I19 (EH1) at Diamond Light Source (Didcot, UK) using silicon double crystal monochromated synchrotron radiation (λ = 0.6889 Å) and a Dectris Pilatus 2M detector TGA: TGA measurements were performed on a Netzsch TG 209F1 Libra coupled with a Mass Spectrometer. Samples (ca. 10 mg) in alumina crucibles were subjected to heating/cooling procedures (30 °C to 1000 °C at 10 °C/Min) under a nitrogen (N2) atmosphere. Methods and software for processing the data: DSC: All DSC data were analysed using TA Instruments TRIOS software version 5.1.1. Gas sorption: Analysis was performed with Micromeritics Flex Version 6.03 software. H NMR: All spectra were analysed with MestReNova version 12. 0. 2 20910 software. PDF: Data was processed using the GudRunX software. PDF analysis was performed using PDFgui PXRD: Simulated PXRD patterns were refined against experimental data using TOPAS academic (V.7) software Solid State NMR: The NMR data was processed using Topspin 5.0, and the data were fitted to this equation within the MATLAB 2025b Curve Fitter app. All directly excited 13C MAS NMR spectra were deconvoluted using the solid line shape analysis tool “sola” in Topspin 5.0 to extract the relative linker ratios SCXRD: The structure was solved using SHELXT7 and refined by full-matrix least-squares on F^2 using SHELXL,7 integrated within Olex2.8 All hydrogen atoms were placed geometrically and refined using a riding model. All heavy atoms were refined anisotropically. The SQUEEZE9 routine of PLATON10 was used to remove the scattering contribution of disordered solvent voids. TGA: All TGA data produced were analysed with Netzsch Proteus-Thermal Analysis 6.1.0 software - People involved with sample collection, processing, analysis and/or submission: Name: Harry G. Palmer Email: H.G.Palmer@liverpool.ac.uk ORCID: 0009-0006-6061-6722 Name: Chumei Ye Email: ye.chumei.27c@st.kyoto-u.ac.jp ORCID 0009-0001-6241-1230 Name: Arad Lang Email:aradlang@technion.ac.il ORCID: 0000-0003-3692-7628 Name: Louis Longley Email: L.Longley@liverpool.ac.uk ORCID: 0000-0002-9178-9603 Name: Sam D Harding Email: S.D.Harding@liverpool.ac.uk ORCID: 0009-0003-0401-3829 Name: Jay McCarron Email: jay.mccarron@liverpool.ac.uk ORCID: 0009-0008-0446-8088 Name: Frédéric Blanc Email: Frederic.Blanc@liverpool.ac.uk ORCID: 0000-0001-9171-1454